Breaking News
December 15, 2018 - Young people suffering chronic pain battle isolation and stigma as they struggle to forge their identities
December 15, 2018 - Lifespan extension at low temperatures depends on individual’s genes, study shows
December 15, 2018 - New ingestible capsule can be controlled using Bluetooth wireless technology
December 15, 2018 - Researchers uncover microRNAs involved in the control of social behavior
December 15, 2018 - Research offers hope for patients with serious bone marrow cancer
December 15, 2018 - Link between poverty and obesity is only about 30 years old, study shows
December 15, 2018 - Mass spectrometry throws light on old case of intentional heavy metal poisoning
December 15, 2018 - BeyondSpring Announces Phase 3 Study 105 of its Lead Asset Plinabulin for Chemotherapy-Induced Neutropenia Meets Primary Endpoint at Interim Analysis
December 15, 2018 - Study finds that in treating obesity, one size does not fit all
December 15, 2018 - Tenacity and flexibility help maintain psychological well-being, mobility in older people
December 15, 2018 - Study reveals role of brain mechanism in memory recall
December 15, 2018 - High levels of oxygen encourage the brain to remain in deep, restorative sleep
December 15, 2018 - Experimental HIV vaccine strategy works in non-human primates, research shows
December 15, 2018 - Genetically modified pigs could limit replication of classical swine fever virus, study shows
December 15, 2018 - FDA Approves Herzuma (trastuzumab-pkrb), a Biosimilar to Herceptin
December 15, 2018 - Cost and weight-loss potential matter most to bariatric surgery patients
December 15, 2018 - Cancer Research UK and AstraZeneca open new Functional Genomics Centre
December 15, 2018 - New research lays out potential path for treatment of Huntington’s disease
December 15, 2018 - Prestigious R&D 100 Award presented to Leica Microsystems
December 15, 2018 - Study shows septin proteins detect and kill gut pathogen, Shigella
December 15, 2018 - Study sheds new light on disease-spreading mosquitoes
December 15, 2018 - 2017 Saw Slowing in National Health Care Spending
December 15, 2018 - Monitoring movement reflects efficacy of mandibular splint
December 15, 2018 - Study supports BMI as useful tool for assessing obesity and health
December 15, 2018 - Self-guided, internet-based therapy platforms effectively reduce depression
December 15, 2018 - Organically farmed food has bigger climate impact than conventional food production
December 15, 2018 - Faster, cheaper test has potential to enhance prostate cancer evaluation
December 15, 2018 - Researchers study abnormal blood glucose levels of patients after hospital discharge
December 15, 2018 - Swedish scientists explore direct association of dementia and ischemic stroke deaths
December 15, 2018 - Study finds 117% increase in number of dementia sufferers in 26 years
December 15, 2018 - Eczema Can Drive People to Thoughts of Suicide: Study
December 15, 2018 - Link between neonatal vitamin D deficiency and schizophrenia confirmed
December 15, 2018 - Nurse denied life insurance because she carries naloxone
December 15, 2018 - Ritalin drug affects organization of pathways that build brain networks used in attention, learning
December 15, 2018 - Research pinpoints two proteins involved in creation of stem cells
December 15, 2018 - Gut bacteria may modify effectiveness of anti-diabetes drugs
December 15, 2018 - Early physical therapy associated with reduction in opioid use
December 15, 2018 - Breast cancer protection from pregnancy begins many decades later, study finds
December 15, 2018 - How often pregnant women follow food avoidance strategy to prevent allergy in offspring?
December 15, 2018 - Using machine learning to predict risk of developing life-threatening infections
December 15, 2018 - How imaginary friends could boost children’s development
December 15, 2018 - Folate deficiency creates more damaging chromosomal abnormalities than previously known
December 15, 2018 - Study provides new insights into molecular mechanisms underlying role of amyloid in Alzheimer’s disease
December 15, 2018 - For the asking, a check is in the mail to help pay for costly drugs
December 15, 2018 - UA scientists uncover biological processes leading to rare brain disorder in babies
December 15, 2018 - The largest database on industrial poisons
December 15, 2018 - ESMO Immuno-Oncology Congress showcases novel technologies set to benefit many cancer patients
December 15, 2018 - Ovid Therapeutics Announces Plans to Move into a Phase 3 Trial in Pediatric Patients Based on End-of-Phase 2 Meeting for OV101 in Angelman Syndrome
December 15, 2018 - Left ventricular noncompaction – Genetics Home Reference
December 15, 2018 - Children’s sleep not significantly affected by screen time, new study finds
December 15, 2018 - When should dementia patients stop driving? A new guidance for clinicians
December 15, 2018 - Researchers use INTEGRA’s VIAFLO 96/384 to streamline the experimental workflow
December 15, 2018 - Researchers discover protein involved in nematode stress response
December 15, 2018 - Cancer patients have greater risk of developing shingles, study shows
December 14, 2018 - UAlberta scientists identify biomarkers for detecting Alzheimer’s disease in saliva samples
December 14, 2018 - Study uncovers link between tube travel and spread of flu-like illnesses
December 14, 2018 - Caffeine plus another compound in coffee may fight Parkinson’s disease
December 14, 2018 - GW researchers review studies on treatments for prurigo nodularis
December 14, 2018 - Lack of peds preventive care ups unplanned hospital admissions
December 14, 2018 - Miscarriage: When Language Deepens Pain
December 14, 2018 - New method helps better understand pathological development of ALS
December 14, 2018 - Intellectually active lifestyle confers protection against neurodegeneration in Huntington’s patients
December 14, 2018 - Mammalian collagen nanofibrils become stronger and tougher with exercise
December 14, 2018 - Considerable Morbidity, Mortality Due to Animal Encounters
December 14, 2018 - Researchers find inhibiting one protein destroys toxic clumps seen in Parkinson’s disease
December 14, 2018 - How early physical therapy can lessen the long-term need for opioids
December 14, 2018 - Depression, suicide rates highest in Mountain West states
December 14, 2018 - New model could cure the potential to underestimate how quickly diseases spread
December 14, 2018 - Exercise-induced hormone activates cells critical for bone remodeling in mice
December 14, 2018 - Researchers discover new mechanism behind spread of malignant pleural mesothelioma
December 14, 2018 - Health Tip: Celebrate a Healthier Holiday
December 14, 2018 - Scalpel-free surgery enhances quality of life for Parkinson’s patients, study finds
December 14, 2018 - Early physical therapy can reduce risk, amount of long-term opioid use | News Center
December 14, 2018 - Genetic marker, predictor of early relapse in common childhood cancer discovered
December 14, 2018 - Study could lead to a potential new way of treating sepsis
December 14, 2018 - New protein complex helps embryonic stem cells to maintain their indefinite potential
December 14, 2018 - Salk professor receives $1.8 million from NOMIS Foundation for research on mechanisms to promote health
December 14, 2018 - New discovery will improve the safety and predictability of CRISPR
December 14, 2018 - Geneticists discover how sex-linked disorders arise
December 14, 2018 - New method to visualize small-molecule interactions inside cells
Choosing The Correct Camera for Fluorescence Microscopy

Choosing The Correct Camera for Fluorescence Microscopy

image_pdfDownload PDFimage_print

The camera used in a fluorescence microscope is arguably the most important component, and it can also be the most expensive. As a result, choosing the correct camera for your system is an important decision that should not be taken lightly.

We spoke to Ian Holland, from LUMENERA, about the different factors to consider when looking for a fluorescence microscopy camera, and the range of microscopy cameras that LUMENERA supply.

Why is it important to make an informed choice when choosing a new camera for your fluorescence microscope?

It is important to select the proper camera for fluorescence microscopy which has high sensitivity and low noise, to avoid photo bleaching your sample. A monochrome camera is also preferred for fluorescence imaging because it does not have a color filter pattern superimposed over the image sensor. Since the microscope’s filter wheel selects which wavelength makes its way to the sensor, a monochrome camera allows equal signal detection on all pixels and increases the overall sensitivity of the camera.

Color information is then added by software during image capture to match what is seen in the microscope’s eyepiece.

Every lab is budget-conscious these days, so selecting a camera that meets your needs is important. Choose a dedicated, high-end camera, if your application requires it. However, in other circumstances a single camera can perform well in both a brightfield and a fluorescence environment and cover the tasks typically requiring two cameras – saving money in the process.

Image taken using a Lumenera INFINITY3S-1UR Microscope Camera

What is the QE and peak QE? Are these the most important parameters to consider when choosing a fluorescence camera?

Quantum efficiency (QR) expresses the conversion ratio between photons of a given wavelength and electrons being freed on the image sensor to produce a signal. The higher the QE, the less light is required to fall on each pixel to obtain a usable signal. Peak QE denotes the wavelength at which the camera is best suited to convert photons into electrons. The camera’s overall QE graph indicates the camera’s QE in the range of each dye’s emission wavelength showing whether adequate conversion efficiency exists.

It is also important to note that some vendors express their camera’s QE in terms of relative QE instead of absolute QE. This normalizes the QE curve based on the camera’s peak QE, which would be set to 100%. These graphs are not adequate for camera comparison as only absolute QE can be used to differentiate cameras.

How can camera noise affect fluorescence measurements? Is camera cooling still necessary to successfully capture fluorescence images?

Cameras with both low read noise and low dark current noise are highly sought after in fluorescence microscopy because they produce clearer images and can benefit from the use of higher gain. Read noise occurs every time an image is captured. The lower the read noise, the higher the gain that can be used without deteriorating the image quality. This allows for shorter exposure times which helps to limit dark current noise. The latter form of noise is temperature and time dependent – typically expressed in electrons per second at a given temperature.

The shorter the exposure, the less dark current noise will be present in the image. With advancements in image sensor technology, noise levels have been on the decline by an order of magnitude over the last decade. This greatly reduces the need to cool cameras for most fluorescence applications and allows for significant cost savings for imaging equipment.

Do different types of fluorescence microscopy techniques require different camera specifications?

Many different types of research involve a variety of traditional and newer techniques using fluorescence microscopy. The strength of the emission signal from the sample and how well it endures the excitation energy are the main criteria impacting the sensitivity of the camera being selected.

Also, it is important to know that the camera sensor and/or filters in the optical path are compatible with the emission wavelength from the dyes being used, specifically if the emission lies beyond the visible spectrum (e.g. Near-IR).

Image taken using a Lumenera INFINITY3S-1UR Microscope Camera

How would the requirements for a camera used in multiphoton fluorescence imaging differ?

Multiphoton fluorescence imaging will generate emissions signals in the visible and Near-IR spectrum. So, the camera requirements will be similar for single photon or multiphon fluorescence. The camera selection will still depend on the strength of the signal from the specific dyes, their emission wavelength, and the power of the illumination source.

What problems are associated with using a substandard camera for fluorescence microscopy?

Selecting a microscope camera that is not intended for fluorescence microscopy will introduce significant image quality degradation. The image will either be too noisy to make out finer details in the intricate areas of the sample structure or too long an exposure time will be required to capture enough light, making it difficult to focus and position the sample in the field of view due to the extended time interval between images caused by long exposure times.

Also, many fluorescent dyes will have reduced emissions (photo-bleaching) the longer they are exposed to the light source, and a more light-sensitive camera allows for shorter exposure times, helping to minimize photo-bleaching.

What cameras do Lumenera provide for fluorescence microscopy?

Currently, the Lumenera INFINITY-3 series cameras are best suited for fluorescence applications, specifically the INFINITY-3S -1, our most sensitive and lowest noise camera in our portfolio.

The INFINITY-3-3URC and INFINITY-3-6URC camera models have excellent color reproduction for wide field imaging, while also being sufficiently sensitive to be used for bright fluorescence and allowing a single camera to perform the job typically requiring two separate cameras.

Does Lumenera provide assistance for customers in deciding which camera is best for their application?

Lumenera support is there for you every step of the way, from selecting the right camera for your application and budget to phone and e-mail support if questions arise after the purchase of your camera through our Technical Assistance Center (TAC). Technical support is included in the purchase price of the camera and does not have a time or usage limit.

Does Lumenera have any other advice on designing a robust fluorescence microscopy system?

Selecting the right camera for your application can pay back in dividends down the road. Service, build quality and usability go a long way in ensuring ease of use, product longevity, and reducing downtime in the lab. Lumenera offers an industry-leading four-year warranty on all of our cameras.

We stand behind our products and are committed to providing our customers with meaningful support throughout the life of their camera.

Where can our readers find out more about Lumenera and the cameras you provide for fluorescence microscopy?

Our website has a complete list of our microscopy cameras that are currently available.  And, we can be reached with questions at [email protected].

Download the Brochure for More Information

About Ian Holland   

Since 2005, Ian’s role at Lumenera has been centered around the scientific customer by helping them select which cameras are most suitable for their applications, including digital pathology. He also offers global customer and sales support as part of the TAC team.

As a Senior Applications Engineer, Ian is a product manager for the INFINITY ANALYZE software. His entire career has been focused in customer support and service and has been in the image processing industry since 1985.

 

Tagged with:

About author

Related Articles